Turbochef-technologies TurboChef User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
2
INSTALLATION, SPECIFICATIONS, AND MAINTENANCE
NOTE: The Smart Voltage Sensor Technology does
not compensate for lack of voltage or over-voltage
situations. It is the responsibility of the owner to
supply voltage to the unit according to the follow-
ing specifications.
Power Supply - Europe, Asia-Pacific
NGC EW (3-phase)
Voltage: 400
VAC, 50 Hz, Wye, 5-
wire (3L + N + Ground)
Circuit Breaker: Type D, min. 20 Amps
NGC ED (3-phase)
Universal Voltage: 230
VAC, 50 Hz, Delta, 4-
wire (3L + Ground)
Circuit Breaker: Type D, min. 30 Amps
NGC UK (1-phase)
Voltage: 230
VAC, 50 Hz, 3-wire
(2L + Ground)
Circuit Breaker: Type D, min. 30 Amps
Power Supply - Latin America
NGC BK (1-phase)
Voltage: 220
VAC, 60 Hz, 3-wire
(2L + Ground)
Circuit Breaker: Type D, min. 30 Amps
Power Supply - Japan
NGC JD (3-phase)
Voltage: 200
VAC, 50/60 Hz, Delta,
4-wire (3L + Ground)
Circuit Breaker: Type D, min. 30 Amps
NGC JK (1-phase)
Voltage: 200
VAC, 50/60 Hz, 3-wire
(2L + Ground)
Circuit Breaker: Type D, min. 30 Amps
Power Supply - South Korea
NGC KW (3-phase)
Voltage: 400
VAC, 60 Hz, Wye, 5-
wire (3L + N + Ground)
Circuit Breaker: Type D, min. 20 Amps
POWER INPUT
Heaters Input Power (NA) 5990/6675 watts
Heaters Input Power (Intl) 6300 watts
Microwave Input Power 3500 watts*
*Maximum Independent Input Power
DELIVERY AND PRODUCT PLACEMENT
Remove oven from carton. Immediately note any
damage and contact shipping company within 24
hours in order to file a claim. TurboChef is not
responsible if the product is damaged in shipment.
Remove all literature and accessories from the carton.
NOTE: Thoroughly check the carton before discarding.
WARNING
: Oven weight is approx. 190 lbs.
(86 kg) Two or more persons are required to
lift it.
Lifting and Placing the Oven
Position one or more persons on either side of the
oven and lift from the bottom. Never lift the oven
from the front and rear. Place the oven on a counter-
top surface at least 28” (711 mm) deep and capable of
supporting 200 lbs (91 kg).
Once properly positioned on the counter, plug the
oven into wall-mounted electrical receptacle. See
page ii for grounding instructions.
WARNING
: Never lift the oven by its door
handle. Physical damage to the oven and/or
personal injury may result. The operator must ensure
that the oven is properly placed on the countertop at
all times. TurboChef will not recognize a fallen oven
as a warrantable claim and is not liable for any injuries
that may result.
Built-In Installation (Figure 2)
TurboChef ovens are designed to be installed on a
countertop or table. They are not intended for built-
in or enclosed installation.
“Built-in or enclosed installation” is defined as
installing an oven in any structure that surrounds the
oven by five sides (i.e., top/rear/side panels and base).
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 93 94

Comments to this Manuals

No comments