Turbochef-technologies TurboChef User Manual Page 54

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 53
ADJUSTING THE SECONDARY AND MONITOR
INTERLOCK SWITCHES - NEW SWITCH SETUP
1. Disconnect power to the unit.
2. Disconnect the 40-pin connector from the I/O
board to allow maximum clearance.
3. Using the 0.060” (1.524 mm) spacer as a
template (included with item 74), adjust the
secondary switch.
NOTE: This will also adjust the monitor switch.
4. Open and close the door several times to verify
the switch gap.
NOTE
: The absolute maximum gap should not
exceed 0.060” (1.524 mm).
5. Re-connect the 40-Pin connector to the I/O
board and apply power to the unit.
6. Simultaneously press
BACK and ENTER keys.
7. Enter 9-4-2-8, then press
ENTER.
8. Open the oven door and verify P, S, and M
disengage in sequence.
9. Close the oven door and verify the M, S, and P
engage in sequence.
10.Energize the Microwave System and open the
door.
11.Verify the W indicator is backlit, meaning the
oven microwave system turns OFF when the
door is open.
SECONDARY AND MONITOR SAFETY SWITCH PARTS
Figure 33 and 34
77. 102804 Hinge, Right
78. 102012 Switch, Limit, Micro (x2)
79. NGC-1126 Plate, Door Switch
80. 101914 Standoff, #8-32 F/F x 1”, 5/16”
DIA
81. 101915 Standoff, #8-32 M/F x 5/16”,
1/4” DIA (attached to outside
of Item 80.)
82. 102921 Screw, #8-32 x 3/8”
83. 101558 Screw, 4-40 x 1.125”
FIGURE 33: Secondary/Monitor Adjustment and Parts -
New Switch Setup
79
80
82
x2
83
x2
78
81
82
77
80
82
81
FIGURE 34: Secondary/Monitor Switch Assembly -
New Switch Setup
THE OVEN DOOR